Membrane Conductivity Total Organic Carbon Analyzer – TOC-4800


Applications in the pharmaceutical industry: purified water, water for injection, and cleaning validation;


Product Details


Application


1. Pharmaceutical industry applications: purified water, water for injection, and cleaning validation;

2. Applications in the microelectronics industry: ultrapure water circulation, ultrapure water make-up, diagnostics, and recovery.

3. Drinking Water and Surface Water

 

 

Product Features


1. Utilizing UV persulfate oxidation and thin-film conductivity measurement techniques.

2. Built-in 10-inch display; no separate computer required.

3. Embedded microprinter; measurement data can be printed in real time as needed.

4. The control software is fully compliant with computerized system validation, featuring data integrity, multi-level password access controls, and audit trail functionality.

5. Interference from halide ions and nitrogen-containing ions can be eliminated.

6. The software is easy to use and allows instrument calibration with either the standard reference solutions provided by our company or those prepared by the user. Minimal training is required for operators to become proficient.

7. Wide measurement range: capable of detecting low-conductivity deionized water such as purified water and water for injection, as well as high-conductivity wastewater, rinse water, drinking water, and surface water.

8. Features an automatic alarm function that activates when the set upper limit is exceeded.

9. The design is simple, allowing customers to independently replace consumables such as oxidants, UV lamps, peristaltic pump tubing, and ion-exchange resins.

10. Service-life countdown function for oxidants, UV lamps, peristaltic pump tubing, ion-exchange resins, and other components

11. Can be connected to an autosampler for unattended operation.

12. The instrument’s performance meets the requirements of the Pharmacopoeia and the National Standard for Drinking Water.

 

Technical Specifications


TOC detection range: 0–20,000.0 µg/L

Decomposition Principle TC: UV Persulfate

Detectable parameters: TC, TIC, TOC, conductivity, temperature

TOC detection accuracy: 0.1 µg/L

Accuracy error: ≤±5%

Repeatability error: ≤3%

Linearity: R² ≥ 99.9%

Water sample conductivity requirement: <1000 µS/cm at 25°C